Easy Monitoring Kit: temporary monitoring of electrical consumption

Real load profiles in minutes, with no wiring. A portable wireless kit you install on site and check remotely, in real time. Once the measurement campaign is over, you move it to the next customer.

LoRaWAN wireless · real-time data · cloud dashboard · plug&play · AL300 gateway · current monitoring

How the Easy Monitoring Kit works in 3 steps: clip the current probes onto the cables, the AL300 gateway sends the data to the cloud via 4G, view consumption remotely on the Optimo IoT platform
How the Easy Monitoring Kit works in 3 steps: clip the current probes onto the cables, the AL300 gateway sends the data to the cloud via 4G, view consumption remotely on the Optimo IoT platform

Who is the Easy Monitoring Kit for

For consultants, designers, energy managers and anyone who needs to know the real load profiles of a facility for a limited period, without installing a permanent monitoring system.

Energy consultants and certified energy experts

Energy audits and feasibility studies built on data measured directly on site, rather than on estimates.

Electrical designers

The real load profile of each load, to size transformers, lines or expansions based on actual consumption.

ESCOs and energy managers

The on/off cycles of generators and machines, to know before proposing an efficiency measure.

Maintenance and facility managers

The operating status of machines, to investigate an anomaly or suspicious consumption.

Companies

Where energy is consumed, with the data needed to calculate energy intensity KPIs.

✕ THE PROBLEM

Problem: Spot readings with a clamp meter and photos on WhatsApp

Everyday reality: an on-site measurement campaign made of spot readings and dependent on the availability of whoever works at the facility.

Anyone working in electrical design or energy audits often has to reconstruct the load profiles of a customer’s loads. The most common method is also the most laborious: a few clamp meter readings during the site visit, then asking the customer’s electrician to repeat them over the following days.

The readings arrive as photos of the display on WhatsApp, whenever the electrician has time. In the end, the load profile is still an estimate.

  • ✕Inaccurate data. A few instantaneous values, profiles reconstructed with estimates.
  • ✕Wasted time. Coordinating the electrician, going back on site, chasing the readings.
  • ✕Missing measurements. When a reading is needed, there’s often no one available to take it.
Customer's electricianlast seen yesterday
Photo of the clamp meter on the compressor cable

Compressor line, 10:32 AM

I can't read it clearly, could you take another photo?

Can't right now, I'll send it on Monday

A scenario every energy auditor knows well

From spot measurements to real-time monitoring

✕ THE PROBLEM

Everyday reality

  • ✕Spot readings with a clamp meter
  • ✕Values sent as photos, at random times
  • ✕Load profiles reconstructed from estimates
  • ✕Repeated site visits for every reading
✓ THE SOLUTION: EASY MONITORING KIT

A new way of working

  • ✓Continuous measurement, one reading every minute
  • ✓Data on the platform, visible in real time
  • ✓Load profiles measured, not estimated
  • ✓Data analysis from the office, via cloud and AI integration

✓ THE SOLUTION

The Optimo IoT solution: portable plug&play monitoring

The Easy Monitoring Kit is made up of two elements: the AL300 gateway and the LoRaWAN wireless current probes. Installation is immediate and there are no cables to run: ask the electrician to clip the clamp-on probes onto the loads and start monitoring right away.

AL300 Gateway

Receives data from the probes via LoRaWAN and sends it to the cloud over a SIM with the built-in 4G modem: no customer network needed.

LoRaWAN current sensors

Single-phase and three-phase, wireless and battery-free: they are powered by the current flowing through the monitored cable. They clip onto the load cables and transmit data by radio over the LoRaWAN protocol.

What the current probes can measure

A · every minute

Instantaneous current

The real load profile of each load, minute by minute.

Ah · cumulative

Cumulative current

Current accumulated over time, to compare different periods and loads.

kWh · estimated

Estimated energy

An estimate of the energy consumed, which you can refine on the platform with virtual variables.

Grafico a barre degli ampere-ora giornalieri di quattro utenze monitorate con sonde di corrente

From left: currents of several loads compared, daily ampere-hours of an ice cream shop (closed on Mondays) and hourly consumption. Always available: historical trends, hourly and daily aggregates, CSV export, virtual variables and alarms.

How to use the data

Energy audit

Find out which loads consume the most, with which duty cycles and load profiles.

  • Most energy-intensive loads to put under permanent monitoring
  • Duty cycles and idle consumption
  • Measured data baseline for improvement proposals

Design and energy efficiency

Know the real loads to correctly size systems and interventions.

  • Transformer sizing
  • Line efficiency improvements
  • Expansions and new loads

Facility maintenance

Track how machines are running without having to be on site.

  • Machine on/off cycles
  • Alarms for abnormal current draw
  • Plant room consumption isolated from the rest of the facility

Business management

Bring electricity consumption into everyday decisions.

  • Energy intensity KPI calculation
  • Consumption of individual stores
  • Optimized air conditioning switch-on times

A measurement campaign, step by step

A consultant needs to prepare an energy audit for a manufacturing company and understand how the main loads operate: compressor, production line, air conditioning and lighting.

Day 1

Installation

During the site visit, the electrician clips the probes onto the load lines. The gateway connects via 4G and the first data appear on the platform right away.

Weeks 1-3

Data collection

The system records the current minute by minute, day and night, weekends included. The consultant checks from the office that everything is transmitting.

Analysis

Real load profiles

Export the data and identify duty cycles, peaks and idle consumption: for example, a compressor that keeps running over the weekend.

End of campaign

Removal and reuse

The probes are unclipped and the kit is ready for the next customer, with nothing left installed at the facility.

Please note: what this solution is not

The Easy Monitoring Kit is not a complete energy monitoring system designed to measure all the electrical parameters of the loads. For voltage, power, active and reactive energy, phase shift and harmonics you need power analyzers or MID meters installed in the panel: a more complete system, but also more expensive and demanding to install.

It’s the right choice when you need permanent monitoring with MID-certified measurements. For a measurement campaign, however, that level of detail rarely justifies the investment.

 Easy Monitoring KitEnergy Monitoring Kit
PurposeMeasurement campaigns, load profilesPermanent monitoring, monitoring plans for energy audits
InstrumentsLoRaWAN current probes and AL300 gatewayMID meters and power analyzers in the panel
QuantitiesCurrent, Ah, estimated energyVoltage, current, power, active and reactive energy, cosφ, harmonics
InstallationFast, no wiringWired, in the panel
ReusableYes, from one site to the nextNo, it’s a permanent system

FAQs

A single AL300 handles all the probes of a typical measurement campaign, even if they are installed in different panels: the LoRaWAN Network Server is built into the gateway. For very large facilities, we’ll assess with you at the proposal stage whether a second gateway is needed.

LoRaWAN is designed to cover long distances, even through walls and floors, and in many plants a single gateway reaches every panel. The actual range depends on metal structures, steelwork and antenna position: that’s why we check it with you on the floor plan before shipping the kit.

No. The AL300 connects to the cloud through its built-in 4G modem and a data SIM, so there’s no need to access the corporate network or involve the customer’s IT department. If the panel is in an area with poor signal, an external 4G antenna with a 3-metre cable is available.

It depends on what you want to observe. A few days may be enough to understand the cycle of a single machine; a representative profile of a company usually takes one to three weeks, so as to include different shifts and at least one weekend.

The probes are split-core CTs: they clip around the cable without disconnecting anything and without stopping the load. However, reaching the cables means working inside the panel, so installation must be done by a qualified electrician, following the facility’s safety procedures.

The probes measure current, not voltage or power factor. Energy is calculated on the platform with virtual variables that use a nominal voltage and a reference cosφ: the result is suitable for comparing loads and understanding where energy is consumed, not for billing. If you measure voltage and cosφ with a spot reading, you can enter them in the calculation to refine the estimate. For certified measurements you need the Energy Monitoring Kit with MID meters.

Plan your next measurement campaign

Tell us about the facility and the loads to monitor: we’ll suggest the most suitable kit configuration.

Improve your workflow with the Easy Monitoring Kit